Part Number:
ETI0001-1245
Rugged Mil Spec® DC UPS
24 VDC Power Source with
6 Hour Backup at -30°C
Rugged Rack or Fixed Mount, Military Grade
120 Watt DC UPS w/ Wide Range Input and
Dual Hot Swappable Battery Modules
Providing 6 Hours of Backup Down to -30°C
ETI0001-1245 Rugged Mil Spec DC UPS Standard Front Panel Layout
ETI0001-1245 Rugged Mil Spec DC UPS Standard Rear Panel Layout
The field proven Rugged Systems™ UPS line is ideally suitedfor military, industrial and telecommunications applications requiring a ruggedrack, vehicular or field deployable, high reliability, compact size and lightweight design. The “1245” is being used guidance systems in harshenvironments because of the stringent performanceand reliability requirements. The heavy-duty chassis, occupying only 7.0” (4U) by14.0” depth, has rounded metal corners and rugged handles frontand rear, aiding in safe handling. Internally, all major components are wellsecured and electrically insulated to prevent damage due to shock andvibration. The internal EMI/RFI filters minimize input current harmonics. Toprovide added flexibility and reliability, the “1245” accepts two independenthot swappable Battery Modules. This system is designed to provide full outputfor 6 hours following an AC power outage even when the external temperature isbelow freezing. The LED arrays keep the operatorinformed as to the unit's status including load and battery levels. Allcontrols and protective devices are brought to the front panel. Further, all front panel devices areguarded toprevent damage or accidental operation. The input switch and the isolation provide double pole isolation for shipboard systems.
The rear panel provides locking connectors for the inputand output power. Removable and washable air filters and a high capacity ballbearing fan provide added protection in both controlled and hostileenvironments. The status connector provides an interface with optional computer softwareproviding loss of AC and low battery status as well as remote shut down capability.
Overall, the Rugged Power line is uniquely qualified for criticalshipboard, vehicle, airborne or land based systems combining advanced modular designfeatures with highly reliable construction.
DC OUTPUT | |
Output voltage: | 24 VDC standard, other voltage levels optional |
Output rating: UPS | 120 watts standard, other power ratings optional |
Non-linear load capacity: | Up to 100% non-linear load capability w/o derating |
Output voltage regulation: UPS | ± 1.0% static regulation of nominal ± 2.0% dynamic (0 to 50% load step) |
Overload surge capacity: | 110% for 10 minutes; 125% for 30 seconds |
Operational status | Status, load and battery LEDs, w/contacts +90 dB audible alarm, alarm on/off inhibited |
Output protection: | Front panel mounted fuse (F6) |
AC INPUT | |
Input voltage selection: | Autoranging Input of 85-265 VAC |
Input frequency: | From 46 Hz to 440 Hz |
Input/output isolation: | 120 dB common mode, <5 mA leakage |
Input transient suppression: | Complies with IEEE 587 and UL 1449 |
Input control/protection: | Guarded 3 pole switch (S1) w/fuse (F2A and F2B) |
Input power connection: | MS3102E20-19P, 3 pin, locking |
BATTERY MODULES | |
Battery type: | Maintenance free immobilized electrolyte, Flame retardant materials (Oxygen Index 28+) |
Battery life: | Rated for continuous service life of 5 years |
Battery protection: | Front panel mounted fuse (F1) |
Battery backup time: 2 Module | 360+ minutes at 100% load, 720+ minutes at 50% load |
DISTRIBUTION PANEL | |
Output circuits: | One DC output standard |
Output control: | Optional remote control panel w/rocker switches |
Output receptacles: | DC output MS3452W18-11S, 5 pin locking |
MECHANICAL | |
Dimensions ( H x D x W ): | 7.0 (4U) x 14.0 x 19.0 in (178 x 356 x 483 mm) |
Rack Slide Mount Patterns: | General Devices pattern |
Alternate Mounting Options: | Table, Wall, Floor, Portable, Horizontal/Vertical |
Unit weight: UPS | 140 lb. (64 kg) |
Audible noise: | Less than 47 dB @ 5.0 ft., ANSI "A" scale |
Cooling type: | High capacity, positive pressure, forced air |
Cooling air direction: | Rear intake; exhaust to sides |
Air intake filter: | Washable metal filter media, others optional |
ENVIRONMENTAL | |
Storage temperature: | -13° to 140° F ambient (-25° to 60° C) |
Operating temperature: | -22° to 140° F ambient (-30° to 60° C) |
Operating humidity: | 0 to 95% relative humidity (non-condensing) |
Storage elevation: | Up to 40,000 ft (12,192 m) |
Operating elevation: | Up to 15,000 ft (4,572 m), higher optionally |
STANDARDS | |
United States: | Meets UL-1778 standard for UPS equipment, MIL STDs 167-1, 454, 810, 901D, 1399-300A, & 2000 |
Canada: | CSA C22.2 No. 107 UPS safety requirements |
EMI Protection: | EMI/RFI FCC Part 15, Class A; EN55022; MIL STD 461 |
OPTIONAL ACCESSORIES | |
Emergency Power Off, Elapsed Time Meter, Alternate I/O Configurations, Dual Source Input, Battery Expansion, Batteryless Operation, Battery Charger/Conditioner, Power Distribution Units, Software Interface, Asynchronous serial COM port, 10BaseT Ethernet SNMP/HTTP port, Transport Cases, Slides and Mounting Kits |
March 18