Part Number: ETI0001-1060
Rugged COTS 1000 VA Rackmount UPS

Condor / Egypt Standard Product
Standard N1 Configuration, PowerStationÔ Isolated UPS
85-270 VAC, 46-70 Hz Input, 230 VAC, 50 Hz Output
1000 VA Rugged Rack Mount, Modular Power System

ETI0001-1060 Rugged COTS UPS Front View
ETI0001-1060 Rugged COTS UPS Standard Front Panel Layout

ETI0001-1060 Rugged COT UPS Rear View
ETI0001-1060 Rugged COTS UPS Standard Rear Panel Layout

The field proven PowerStation UPS line is ideally suited for military, industrial, computer and telecommunications applications requiring high reliability, rugged construction, compact size and light weight design. These units are equally suited for use in shipboard, airborne, vehicular, field deployed or fixed locations with controlled or uncontrolled environments. The ETI0001-1060 was initially designed for Condor for use in Egypt's hostile environment. 

The heavy-duty chassis occupies only 3U (5.25") of rack space while delivering up to 1000 VA of clean, uninterruptible power. The rounded metal corners and rugged handles, aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration. The optional mounting kit includes flanges and legs for either horizontal or vertical positioning. 

The internal shielded input transformer provides galvanic isolation with provisions for autoranging domestic (115 VAC, CONUS) and international (230 VAC, OCONUS) input voltages. For field deployed scenarios, the Cold Start feature allows the unit to run from its battery module before external AC is available. The input switch and the galvanic isolation transformer all provide a  double pole isolated source for shipboard systems or overseas locations where phase references and grounding are not consistent. 

The LED arrays keep the operator informed as to the unit's status including load and battery levels. The high intensity audible alarm can be heard in high noise environments, yet is easily adjustable to suit quieter conditions. All controls and protective devices are brought to the front and rear panels with critical switches or breakers guarded. Further, all front panel devices are recessed to prevent damage or accidental operation. Various optional power distribution controls are available which mount on the front panel or remotely. 

The rear panel provides locking connectors for the input and output power. Multiple input and output power panel options are available. A removable and washable intake air filter and high capacity stainless steel ball bearing fan provide added protection in both controlled and hostile environments. The air is drawn from the rear and exhaust air is diverted out the front vent, with alternate air flow directions optional. The external battery connector allows the safe and easy addition of extra battery modules without having to shut the unit down. The batteries are maintenance free with immobilized electrolyte and are constructed of flame retardant materials. For more information, see the Battery Technology section. The unit also operates as a frequency converter, taking 47-70 hertz input and converting it to 50 hertz power. A frequency selection switch is available for those sites requiring 60 hertz output instead of the standard 50 hertz. The Status connector provides an  interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.

See the Power Distribution Units section for a listing of stand alone PDUs. See the N5 Series ETI0001-1402 for a version of this UPS with an integrated PDU and remote control.

Overall, the PowerStation line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction

Technical Specifications: 
P/N: ETI0001-1060

AC OUTPUT
Output voltage: UPS 230 VAC true sinewave standard, up to 600 VAC optional
Output rating: UPS 1000 VA standard in 3U chassis
0.65-0.75 pf standard, optional configurations to 24,000 VA
Non-linear load capacity: UPS Up to 100% non-linear load capability w/o derating
Output voltage regulation: UPS ± 3.0% static regulation of nominal
± 4.0% dynamic (0 to 50% load step)
Overload surge capacity: UPS 110% for 10 minutes; 125% for 30 seconds
Harmonic distortion: UPS Less than 5.0% into 100% non-linear load
Output frequency: UPS 50 or 60 Hz ± 2.5% synchronized to utility
50 or 60 Hz ± 1.0% w/ utility not available
400 or 1000 Hz output available as an option
Operational status Status, load and battery level LEDs, w/contacts
Adjustable level,+90 dB audible alarm w/on/off
AC INPUT
Input voltage selection: Nominal autoranging input 115 / 230 VAC
Input voltage tolerance: UPS 85-270 VAC @ full load without using battery, to 70 VAC @ 75% load
Input frequency: From 46 Hz to 70 Hz standard, optional to 440 Hz
Input/output isolation: 1250 VA, up to 120 dB common mode, <5 mA leakage
Input transient suppression: Complies with IEEE 587 and UL 1449
Input control/protection: Guarded 2 pole circuit breaker w/ fuse
Guarded cold start to turn on w/o AC present
Input power connection: MS3102R-22-2, 3 pin locking, various options
INTERNAL BATTERY
Battery type: Maintenance free immobilized electrolyte,
Flame retardant materials (Oxygen Index 28+)
Battery life: Rated for continuous service life of 5 years
DC protection: Front panel mounted fuse standard, breaker optional
Battery expansion: Up to 24 hours w/ Battery Expansion Modules
DISTRIBUTION PANEL
Output circuits: Six outputs standard, up to eight optional
Output control: Master output circuit breaker
Optional remote interlock ON/OFF control
Output receptacles: IEC320-15R w/cable bales standard, various options
MECHANICAL
Dimensions ( H x D x W ): UPS 5.25 (3U) x 23.5 x 19.0 in (133 x 597 x 483 mm)
Rack Slide Mount Patterns: Jonathan, General Devices patterns standard, others optional
Alternate Mounting Options: Table, Wall, Floor, Portable, Horizontal/Vertical
Unit weight: 100 lb. (45 kg) with lift handles front and rear
Audible noise: Less than 47 dB @ 5.0 ft., ANSI "A" scale
Cooling type: High capacity, positive pressure, forced air
Cooling air direction: Rear intake, exhaust to front, others optional
Air intake filter: Washable metal filter media, others optional
ENVIRONMENTAL
Storage temperature: -13° to 140° F ambient (-25° to 60° C), lower/higher optional
Operating temperature: 32° to 113° F ambient (0° to 45° C ), lower/higher optional
Operating humidity: 0 to 95% relative humidity (non-condensing)
Storage elevation: Up to 40,000 ft (12,192 m)
Operating elevation: Up to 10,000 ft (3,048 m), higher optional
STANDARDS
United States: Meets UL-1778 standard for UPS equipment,
MIL STDs 167-1, 454, 810, 901D, 1399-300A, & 2000
Canada: CSA C22.2 No. 107 UPS safety requirements
EMI Protection: EMI/RFI FCC Part 15, Class A standard; MIL STD 461 optional
OPTIONAL ACCESSORIES
  Autoranging International Input, Emergency Power Off, Elapsed Time Meter, Alternate I/O Configurations, Dual Source Input, Battery Expansion, Batteryless Operation, Battery Charger/Conditioner, Power Distribution Units, Software Interface,  Asynchronous serial COM port, 10BaseT Ethernet SNMP/HTTP port, Transport Cases, Slides and Mounting Kits

This page was last modified on: May 03, 2008
The N5 is one of the most popular configurations for new programs!

Information Request Form

Select the items that apply, and then let us know how to contact you.

Send product literature
Have an engineer contact me
Have a salesperson contact me
I prefer to be contacted by Email   Telephone  Fax  Regular mail
My requirement is immediate  1-3 months  3-6 months  Future

Name
Title
Company
Address
Email
Phone
Fax

To Better Help
You, Please
Describe Your
Requirements

ETI PowerStation UPS are the proven Standard!

Home Up

Send questions or comments about this web site to webmaster@ruggedsystems.com.
Copyright © 1991- 2008 Energy Technologies, Inc. All Rights Reserved. Last modified: August 13, 2008

1stEnergy™, 1stPower™, 24-7Backup™, 911power™, AC24-7™, ACanytime™, ACanywhere™, ACbackup™, ACintegrity™, AirborneBackup™, AirbornePower™, ArmyBackup™, BackupAC™, BackupSource™, BackupTheWeb™, BattlePower™, BlackoutPrevention™, BusinessBackUPS™, cleanUPS™, ControllingPower™, DC24-7™, DCbackup™, DCintegrity™, EcoPowerSource™, eDocsPort™, EnergyTech™, ETI™, ExtremePowerSource™, FuelCellUPS™, GlobalPowerSource™, GlobalUPS™, HomelandBackup™, HomelanSecurity24-7™, ImprovedPower™, IndustrialBackup™, InfoBackup™,  IntelligentUPS™, InternetPowerManager™, LabPower™, LabUPS™, LightUPS™, KnowPower™, MarineCorpBackup™, MarineCorpPower™, MedicalAC™, MedicalBackup™, MilitaryBackup™, NavigationPower™, NavyPower™, NetworkPowerManager™, NonStopAC™, OfficeUPS™, OnsiteBackup™, openUPS™, PersonalSource™, PetroChemPower™, PipelinePower™, PortablePowerPlant™, PoweringTheNet™, PowerProtection™, PowerSecurity™, PowerStatus™, PreventingBlackouts™, RedundantPower™, RenewableSource™,  RuggedPower™, RuggedSystems™, SCADApower™, SecurityGatePower™, ShipboardPower™, SignalBackup™, SolarBackup™, SolarPowerSource™, TacticalComputers™, TacticalComputerWorkstations™, TelecomBackup™, TelecomPowerSource™, ThePowerConnection™, TrafficBackup™, TrafficSignalBackup™, UPStart™, UtilityBackup™, windUPS™, WarfighterBackup™, WarfighterPower™, and WorldPower™ are trademarks of Energy Technologies, Inc.

Diplomatic Power®, Extreme UPS®, Industrial Power Source®, Military Power®, Tactical Fuel Cells®, Tactical Generator®, Tactical Inverter®, TacticalPower®, Tactical Power Plant®, Tactical Solar® and Tactical UPS® are registered trademarks of Energy Technologies, Inc.

Legal Statements